High Performance Centrifugal Partition Chromatography!
  • Preparative LC ? Yes.
    Effectively separate, isolate and purify
    Milligrams to Multigrams!

  • Semi-Prep LC ? Yes.
    High Efficiency, Ultra-selectivity, Short run times

What is HPCPC? Products Background Applications

The CPC-240 system is pictured.
  • flow rate: 0.1- 30ml/ minute
  • Volume: 240ml

Interested? Call 800 867 6690 in USA, or Email us!

Triad Scientific specializes in chromatography and analytical instruments, and we bring interesting new technologies to your laboratory.

For more information, call our (800) number, use the email link, or visit our main web pages at: TRIADSCI We're in Manasquan, NJ. Please visit us at the beach.
This is a scalable system, meaning you can start with a smaller unit, prove your concept, and immediately ramp up to the big boy.

The CPC80 and 240 cover most development-scale use, and let you start out with up to 10g per run.

The larger instrument will handle up to 5 liters, and purifies as much as 100g per run.
Model CPC80 CPC240 CPC1400 CPC5400
Rotational Speed

Washing Speed
Separation Speed
0 ~ 2000 rpm (100 rpm steps)

300 rpm
1500 rpm
0 ~ 1500 rpm (100 rpm steps)
300 rpm
1100 rpm
0 ~ 1300 rpm (100 rpm steps)
300 rpm
1000 rpm
Flow Rate
Washing Flow
Separation Flow
0.1 ~ 30 ml/min
20 ml/min
5 ml/min
1 ~ 200 ml/min
80 ml/min
25 ml/min
10 ~ 500 ml/min
200 ml/min
100 ml/min
Standard Valves 4-way mode switching valve 4-way mode switching valve
6-way sample injection valve
Display LCD Display
Rotor Material Polly-phenylenesulfide (PPS), Stainless Steel Poly-chlorotrifluoroethylene (DAIFLON),
Stainless Steel
Number of Disk 4 pcs x 1 Pack 12 pcs x 1 Pack 18 pcs x 1 Pack 13 pcs x 2 Packs
Rotor Dimension 200 x 20 H mm 200 x 80 H mm 300 x 150 H mm 300 x 380 H mm
Rotor Volume 80 ml 240 ml 1400 ml 5400 ml
Partition Cells 712 2136 1296 1040
Cell Length 15 mm 29 mm 46 mm
Centrifugal Radius 82.5 mm (average) 120 mm (average) 111 mm (average)
Estimated Separation/Run 3 gm/run 10 gm/run 50 gm/run 100 gm/run
Maximum Pressure 60 kg/cm2
Safety Device The rotor is automatically stopped when its lid is opened
In/Out Line Tubing Size 1/16" PEEK (0.75 ID x 1 mm OD) 1/8" SUS x 2 mm OD
Rotor Net Weight 5 kg 7 kg 25kg 40 kg
Overall Dimension 330 W x 475 D x 480 H mm 420 W x 610 D x 500 H mm 600 W x 810 D x 1060 H mm
Net Weight 40 kg 43 kg 70 kg 290 kg
Power Source AC 100V ~ 240V, 3A, 1 50/60 Hz AC 200 ~220V, 3A,
3 50/60 Hz
Customized sample separations prior to purchase are performed by us at reasonable expense.
* Specifications are subject to change without prior notice.
* Patents for Rotor Joint in Japan and for Rotor in U.S.A.


Monster Laboratories for Lab Robots, HPLC, Analytical Instruments, New and Used Laboratory Equipment.
Last update 5/29/7
Monster Laboratories for Laboratory equipment! Microplate readers, analytical instruments, used lab robots, used HPLCs, Used Lab Equipment our specialty! ©2004 Mad Joe Industries